VM600 ABE056 Ultra Slim Racks

(houses the MPC4 mechanical protection card)

Key Features and Benefits

– From the vibro-meter® product family

– 19-inch slim rack with 1U standard height

– Rugged metal construction

– Modular concept allows the addition of specific modules (cards) for machine protection or condition monitoring

– Rack or panel mounting

– Backplane supports open collector (OC) bus and www.honeywell-diver.com power distribution for VM600Mk2/VM600 systems

– Integrated AC input or DC input power supply

– Power check relay

Applications

– VM600Mk2/VM600 Mechanical Protection and/or Condition Monitoring Systems

VM600Mk2/VM600 Mechanical Protection and/or Condition Monitoring Systems

The VM600Mk2/VM600 ABE056 slimline rack is used to house the hardware for the VM600Mk2/VM600 series of machine protection and/or condition monitoring systems in the Vibrometer® product line.

The VM600Mk2/VM600 ABE056 slimline rack has a standard height of 1U and provides mounting space (rack slots) for a single wide VM600Mk2/VM600 processing module (card pair) and a relay module (card).

This rack is particularly suitable for industrial environments where the equipment must be permanently installed in a 19-inch cabinet or panel.

Different versions of the integrated RPS1U power supply can power the VM600Mk2/VM600 ABE056 slimline racks from an external AC or DC power supply.

Both power supplies support a wide input voltage range.

The rack has an integrated backplane that provides electrical interconnection between the integrated power supply (RPS1U) and the installed VM600Mk2/VM600 modules (cards).

The rack also has a power check relay on the rear of the rack to indicate if the integrated power supply is functioning properly.

The VM600Mk2/VM600 Processing Module (Card) is mounted at the front of the rack and the associated Input/Output Module (Card) is mounted at the rear of the rack.

The input/output modules (cards) provide connectors for connecting sensors/measurement chains and for sharing various signals with external systems such as DCS or PLC.

In general, the VM600Mk2/VM600 ABE056 Ultra Slim Racks are factory-configured before shipment and are therefore ready for use.

Optionally, each module (card) can be reconfigured to meet the needs of a specific machinery monitoring application.

Each module (card) can be reconfigured to meet the needs of a specific machinery monitoring application using the appropriate software package from Meggitt Vibro-Meter: VibroSight® or VM600 MPSx.

SPECIFICATIONS

OVERVIEW

Housing: Painted galvanized steel sheet

Color: Off-white (RAL 9002)

Power supply: Integrated RPS1U power supply for VM600Mk2/VM600

The integrated RPS1U power supply provides +5 VDC and ±12 VDC for the VM600Mk2/VM600 and all installed modules (cards).

See also AC Input Power on page 3 and DC Input Power on page 3.

Power Input: The power input has an AC or DC connector (with RFI filter) and an on/off switch.

See Ordering Information on page 6 for information on the main power cord (power strip).

Backplane: Proprietary VM600Mk2/VM600 rack bus (open collector (OC) bus) for data/signal sharing between modules (cards)

Rack Slots (module (card) locations):

Front of rack:

– 1 × slot – module (card) position 01 – for handling modules (cards) such as MPC4Mk2. XMx16. MPC4. or AMC8.

Rear of rack:

– 1 × Slot – Module (Card) Position 01 – For associated input/output modules (cards) such as IOC4Mk2. XIO16T, IOC4T or IOC8T.

– 1 × slot – module (card) position 00 – for the relevant relay module (card), e.g. RLC16Mk2 or RLC16.

Remarks

In general, the associated input/output module (card) is required and the relay module (card) is optional.

For safety reasons, VM600Mk2/VM600 rack slots that do not have a module (card) installed must VM600Mk2/VM600 rack slots that do not have a module (card) installed must be covered by a blank panel.

AC Input Power

Input voltage range: 90 to 264 VAC

Input frequency range: 47 to 63 Hz

Input current: 2.5 A / 115 VAC or 1.5 A / 230 VAC

Output voltage: +5 VDC and ±12 VDC

DC Input Power

Rated input (line) voltage: 24 VDC

Input voltage range: 18 to 58 VDC

Input current: 3.0 A / 24 VDC

Output voltage: +5 VDC and ±12 VDC

Power check relay

Rated input (line) voltage: 110/220 VAC

Rated switching capacity (resistive load)

: 0.5 A / 125 VAC, 0.3 A / 110 VDC, 1 A / 30 VDC

Maximum switching voltage : ±30 VRMS / ±42.4 VAC (peak) or 60 VDC

Maximum switching current : 1 A